Matrix-Type Energy Storage Back-to-Back Routing Test System (2×2.5 MW)
The MatrixLink-PST series is a high-efficiency and high-precision energy management solution tailored for the R&D and validation of advanced energy storage systems. At its core, the system integrates multiple high-precision DC energy storage converters, AC/DC bidirectional regenerative converters with loss compensation, and a high-voltage DC bus. This architecture enables the simulation of complex energy flow scenarios and provides reliable, high-performance testing for various types of energy storage equipment.
Application
![]()
- Overview
- Recommended Products
System Functions
✓ Battery pack capacity testing
✓ Battery pack charge/discharge performance testing
✓ Battery pack charge/discharge efficiency analysis
✓ State-of-charge (SOC) retention and recovery capability testing
✓ Battery pack cycle life testing, including multi-channel cycling tests
✓ Temperature characteristic testing of battery packs
✓ DC internal resistance measurement
✓ Pulse charge/discharge response testing
✓ Dynamic working condition simulation testing
✓ Overcharge and over-discharge rate endurance testing
System Topology Diagram

System Advantages (During Testing)
● High efficiency in feeding power back to the grid
● Patent-grade common DC bus topology enabling energy transfer between channels on the DC side
● DSP + IGBT-based power control architecture for fast and precise energy management
● Margin-based real-time power control algorithm ensures stable and reliable operation
● Configurable output voltage, current, and power ranges, compatible with various battery specifications and models
● 25-year hardware design lifespan (full system uses IGBT modules and film capacitors to ensure product quality)
● Adaptive AC grid connection technology, eliminating the need to distinguish power grid phase sequence
● Advanced software-based phase-locked control technology with active rectification and inversion; total harmonic distortion of input current (THDI) ≤ 5%
Equipment Parameters (Single Channel Parameters)
Key Technical Parameters
| No. | Item | Reference Range / Accuracy Requirement | Remarks |
|---|---|---|---|
| 1 | Equipment Model | PST5000-2CH | 2×2.5MW, supports sequential 2.5MW bidirectional testing |
| 2 | Number of DC Channels | 2 | Channels per cabinet (customizable) |
| 3 | Rated Power per Channel | 2500kW | Supports full power output |
| 4 | Grid Connection Power | 1250kW | For power loss compensation/surplus feedback |
| 5 | Output Voltage Range | 80~1520V | Charging 0V~1520V |
| 6 | Voltage Accuracy | ±(0.05%FS + 0.05%RD) | Higher precision available by customization |
| 7 | Current Range | ±2400A | ±2400A per channel |
| 8 | Current Accuracy | ±(0.05%FS + 0.05%RD) | Higher precision available by customization |
| 9 | Energy Feedback Mode | Tiered AC/DC energy recycling | Prioritize DC-side inter-channel energy recycling; excess energy exchanged with grid |
| 10 | System Efficiency | ≥97.5% | Circulation efficiency |
Device Input Parameters
| No. | Item | Reference Range / Accuracy Requirement | Remarks |
|---|---|---|---|
| 11 | Operating Voltage | AC380V ±15% | Three-phase five-wire (ground resistance ≤ 5Ω) |
| 12 | Operating Frequency | 50Hz ±2Hz | |
| 13 | Power Factor | ≥99% | At half load and above |
| 14 | Current Harmonics (THD) | ≤5% | At half load and above |
| 15 | Input Protection | Undervoltage Protection | |
| 16 | Overvoltage Protection | ||
| 17 | Overcurrent / Overload Protection | Includes breaker overcurrent protection | |
| 18 | Phase Loss Protection | ||
| 19 | Abnormal Frequency Protection | ||
| 20 | Transformer Overtemperature Prot. | ||
| 21 | Lightning Protection | Includes lightning protection components | |
| 22 | Anti-islanding Protection |
Device Output Parameters
| No. | Item | Reference Range / Accuracy Requirement | Remarks |
|---|---|---|---|
23 |
Parallel Mode |
Supports continuous channel parallel |
|
24-1 |
Continuous Sampling Interval |
≤10ms |
Includes current and voltage sampling |
24-2 |
Current Rise Time |
≤50ms |
10%~90% of the current range |
24-3 |
Current Transition Time |
≤100ms |
-90%~90% of the current range |
25 |
Voltage Resolution |
0.1mV |
|
26 |
Current Resolution |
0.1mA |
|
27 |
Power Resolution |
0.1W |
|
28 |
Output Protection |
Undervoltage Protection |
Supported |
29 |
|
Overvoltage Protection |
Supported |
30 |
|
Short Circuit Protection |
Supported |
31 |
|
Overtemperature Protection |
Supported |
32 |
|
Reverse Polarity Protection |
Supported |
33 |
|
Overcurrent Protection |
Supported |
34 |
|
Channel Communication Error Protection |
Output auto shutdown upon comm. failure |
35 |
|
Power-off Protection |
Contactor automatically disconnects |
36 |
|
Emergency Stop Protection |
Includes emergency stop button |
Appearance Design (Reference Design)
Single Channel Dimensions: Width × Depth × Height = 8000mm × 1200mm × 1900mm, Approximate Weight: 12,000kg