Contact us immediately if you encounter problems!

All Categories

Lithium Battery Electrical Performance Test System (750V)

The SDCBUS Series is a high-precision AC/DC power processing system featuring bidirectional power flow for unidirectional and bidirectional load testing.By replacing traditional resistive loads,it minimizes energy loss while enabling grid-connected power control.By eliminating resistive load power consumptio, the system significantly reduces energy loss.

 

Application

Lithium Battery Electrical Performance Test System

 

  • Overview
  • Recommended Products

Lithium Battery Electrical Performance Test System (750V) factory

 

Our SDCBUS Series provides an end-to-end solution for battery pack testing, from cell assembly to final quality assurance. By integrating test equipment, cooling control, communication interfaces, and software, it enables: 

☑ Reliable performance evaluation

☑ Real-time monitoring and logging

☑ Automated data analysis

☑ Smart factory integration 

 

This ensures battery packs meet safety, reliability, and efficiency standards before use in EVs or energy storage systems.

 

Product Features

 

 

1. Patented Topology: Optimal energy-saving control.

2. Core Converter Module Cable-Free Design: Stable, reliable, worry-free operation.

3. Phase-Sequence Independent & Intelligent Locking: Flexible and efficient grid connection.

4. Pure Sine Wave Grid-Tie Control Technology: Zero grid pollution.

5. Automated Testing & Management: Low-barrier efficiency solution.

6. Cost Savings & Longevity: Durable components selected; System design lifespan >15 years.

 

Application

 

1. Comprehensive Electrical Performance Testing for Battery Modules, Packs & Clusters: 

✓   Capacity Test

✓   Charge/Discharge Characteristic Test

✓   Charge/Discharge Efficiency Test

✓   Charge Retention & Recovery Capability Test

✓   Cycle Life Test

✓   Temperature Characteristic Test

✓   DC Internal Resistance Test

✓   Pulse Charge/Discharge Test

✓   Operational Profile Simulation Test

✓   Overcharge/Over-discharge Rate Tolerance Test

 

2. Electronic Load Function & DC Power Supply Aging with Energy Recovery:

●  DC to AC Grid Feedback: 
Efficiently converts DC power into AC fed back to the grid, reducing waste heat from traditional loads.

●  Intelligent Aging Test: 
Simulates equipment aging conditions while achieving low energy consumption, high-precision DC equipment life testing and energy recycling.

 

3. Battery Simulation Function:

●  High-Precision Battery Charge/Discharge Simulation: 
Accurately replicates battery charge/discharge curves, supports dynamic profiles & fault simulation. 

●  High Efficiency (>96% Energy Recovery): 
Reduces test energy consumption while simultaneously validating performance and safety.

 

 

Software Interface Display (During Testing)

 

 

Lithium Battery Electrical Performance Test SystemLithium Battery Electrical Performance Test SystemLithium Battery Electrical Performance Test System




 

 

Specification

 

 

AC-DC (AC Side) Technical Parameters

Parameter Specification
Product Series SDCBUS-750/030-100-2CD
Product Series Code SDCBUS
Maximum DC Output Voltage (V) 750
Minimum DC Voltage Required for Rated Discharge Current (V) / 030
Rated Current per Channel (A) -100
Number of Channels per Cabinet Unit -2
Production Batch D
Dimension (L x W x H mm) 1140 x 950 x 1900
Weight (kg) 1300

 

AC-DC (AC Input Side) Technical Parameters

Parameter Specification
Rated Voltage (V) 380 ±10%
Frequency (Hz) 50 ±2 (Other frequencies customizable)
Power Factor (PF) ≥ 0.99
Current Harmonic Distortion (THDi) < 5% (at >50% load)
AC Input

3-Phase, 5-Wire (PE grounding resistance ≤ 5Ω)

AC Protection Undervoltage, Overvoltage, Overcurrent, Phase Loss, Overload, Frequency Anomaly, Overtemperature, Communication Timeout, Anti-islanding.

 

DC-DC (DC Side) Technical Parameters

Parameter Specification
Cabinet Model 750V 200A - 2 Channels
Max DC Output Voltage 750 V
Min DC Voltage for Rated Discharge Current 30 V
Rated Current per Channel 100 A
Number of Channels per Cabinet 2
Rated Power per Channel (kW) 150
Total DC Output Power per Cabinet (kW) 300
Charge/Discharge Voltage Range (V) 50- 750
Current Range per Channel (A) ±200
Parallel Channel Current Range (A)  ±400 (2 channels parallel)
Energy Feedback Efficiency ≥ 97% (at full load)
Output Voltage Sampling Resolution (mV) 1
Voltage Accuracy per Channel ±0.05% F.S.
Current Accuracy per Channel ±0.05% F.S.
Output Current Sampling Resolution (mA) 1
Continuous Sampling Speed (ms) ≤ 10
Current Rise/Fall Time (ms)  ≤ 5 (10% to 90% of Imax), shockless
Charge/Discharge Transition Time (ms)  ≤ 10 (-90% to 90% of Imax), shockless
Power Resolution (W) 0.1

 

Note: Customization is supported. 

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

1

"Innovate tomorrow, together."
Help us tailor solutions to your requirements by providing your contact information below.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000